Hardware Map

A variable bound to a hardware address does not own its storage. For

VAR_GLOBAL
    start AT %IX0.0: BOOL;
END_VAR

pre-processing creates the global __PI_0_0 and turns start into an alias pointer to it. The constructor binds the pointer. Thus the binary contains both the source variable and its generated storage, as described in Index.

A monitoring tool needs this connection to display the source name with the correct hardware value. The hardware map lists each bound variable’s source name, generated global, and address.

flowchart LR
    parse[Parse] --> index[Index] --> annotate[Annotate] --> validate[Validate] --> codegen[Codegen] --> link[Link]
    validate --> hwmap[Hardware map]
    style hwmap fill:#bfdbfe,stroke:#000,stroke-width:1px,stroke-dasharray:4 3,color:#0f172a

When requested, the map is written after validation and before codegen. It uses only the index. plc --check --hwmap-file=map.json writes it without generating an object file; a normal build can produce both the map and the binary.

The map

The chapter follows one project with the main forms of binding:

FUNCTION_BLOCK Sensor
    VAR
        raw AT %I*: INT;
        alarm AT %QX3.1: BOOL;
    END_VAR
END_FUNCTION_BLOCK

VAR_GLOBAL
    start AT %IX0.0: BOOL;
    speed, speedCopy AT %QW2.5: WORD;
    counter AT %MD1: DWORD;
    sensors: ARRAY[0..1] OF Sensor;
END_VAR

VAR_CONFIG
    sensors[0].raw AT %IW5.0: INT;
    sensors[1].raw AT %IW5.1: INT;
END_VAR

PROGRAM main
    VAR
        stop AT %IX0.1: BOOL;
    END_VAR
END_PROGRAM

Each entry has five fields: the source path (name), generated global (mangled_name), source address (address), direction, and access width. direction is Input, Output, Memory, or Global; access_type is Bit, Byte, Word, DWord, or LWord. For this project:

{
  "VariableMap": [
    { "name": "start",            "mangled_name": "__PI_0_0", "address": "%IX0.0", "direction": "Input",  "access_type": "Bit"   },
    { "name": "speed",            "mangled_name": "__PI_2_5", "address": "%QW2.5", "direction": "Output", "access_type": "Word"  },
    { "name": "speedCopy",        "mangled_name": "__PI_2_5", "address": "%QW2.5", "direction": "Output", "access_type": "Word"  },
    { "name": "counter",          "mangled_name": "__M_1",    "address": "%MD1",   "direction": "Memory", "access_type": "DWord" },
    { "name": "sensors[0].alarm", "mangled_name": "__PI_3_1", "address": "%QX3.1", "direction": "Output", "access_type": "Bit"   },
    { "name": "sensors[1].alarm", "mangled_name": "__PI_3_1", "address": "%QX3.1", "direction": "Output", "access_type": "Bit"   },
    { "name": "main.stop",        "mangled_name": "__PI_0_1", "address": "%IX0.1", "direction": "Input",  "access_type": "Bit"   },
    { "name": "sensors[0].raw",   "mangled_name": "__PI_5_0", "address": "%IW5.0", "direction": "Input",  "access_type": "Word"  },
    { "name": "sensors[1].raw",   "mangled_name": "__PI_5_1", "address": "%IW5.1", "direction": "Input",  "access_type": "Word"  }
  ]
}

speed and speedCopy share an address and the global __PI_2_5. Both names appear in the map. The two alarm members also share one global, __PI_3_1, because their address belongs to the function block declaration rather than to an individual instance.

Generated names combine a direction prefix with the address segments, separated by underscores. %I and %Q both use __PI_ for the process image, %M uses __M_, and %G uses __G_. The size letter is absent, so %QW2.5 and %QX2.5 give the same name and collide. Pre-processing and map generation use the same naming function.

Collecting the entries

Finding the variables is the other half of the work. The map walks the index’s variable-instance iterator twice. That iterator starts at every global variable and every program instance, then goes into their members, level by level.

The first pass takes every instance whose declaration carries a direct address, and skips the templates (AT %I*), because a template has no address until a VAR_CONFIG block gives it one. The address segments are constant expressions in the index: they went through the constant evaluator, so AT %IX0.0 is stored as two evaluated integers.

The instance path is expanded over every array dimension. The one declaration alarm in Sensor therefore gives sensors[0].alarm and sensors[1].alarm, because sensors has two elements, and a three-dimensional array of blocks gives one name per element, in [i,j,k] form.

The second pass reads the VAR_CONFIG entries, which give a concrete address to a template variable. The source path is the path written in the block, and the generated global comes from the configured address, so it matches the global that pre-processing created. The passes cover different declarations, but the map still removes duplicate pairs of source name and generated global.

Files and formats

The collected list is then written to one file. --hwmap-file=<path> selects JSON or TOML by the extension; any other extension is E134. Without a value, the map is written next to the output as <output>.hwmap.json, so plc main.st -o main.so --hwmap-file gives main.so.hwmap.json. The = is required: --hwmap-file map.json makes map.json a source file. The TOML form is the same list as an array of tables:

[[VariableMap]]
name = "start"
mangled_name = "__PI_0_0"
address = "%IX0.0"
direction = "Input"
access_type = "Bit"

Note

Developer note. --hardware-conf=<path> is the older form of the same idea and is deprecated. It writes a HardwareConfiguration list without the generated names and with the address as a list of segment strings, and it lists templates with an empty address, which the new map leaves out because a template maps to nothing. It prints a deprecation warning that points to --hwmap-file.

Where it lives

WhatWhere
Hardware map, deprecated hardware configuration, instance path expansionsrc/hw_map.rs, src/hardware_binding.rs, src/expression_path.rs
Name mangling and pre-processing of addressescompiler/plc_ast
Command line and write stepcompiler/plc_driver